Gc 2010 plus shimadzu pdf

Gc 2010 plus shimadzu s new flagship model, the gc 2010 plus, is the highest performance capillary gc available in the world, providing precise, highspeed tracelevel analysis in a wide range of applications. This system utilizes the new barrier discharge ionization detector technology coupled with a gc 2010 plus capillary gas chromatograph to create a gc system that makes it possible to reveal trace components that are difficult to see by other gc detectors. It also comes with a pdf output function as standard to support the use of fewer. Controls gc 2010 plus, gc 2010, gc 2014, gc 14b a, aoc20is. Simultaneously controls a maximum of four gc or lc units multilicense version permits registering up to 16 units. Fid 2010 plus bestinclass fid sensitivity has been achieved through thorough cleaning of the detector gas line and by incorporating the latest noisereduction technology.

Gas chromatography gc protocol shimadzu gc2010 page 3 of 6 gas chromatography protocol. An hs10 static headspace sampler with transfer line was used for sample preparation and introduction into the gc through the spl. The fourth generation advanced flow controller delivers up to 1200 mlmin, 140. Basic user guide on creating a calibration curve, manually from an extracted data file, to quantitate unknowns utilizing labsolutions lc gc workstation software. Multiple sample runs are setup by clicking on batch processing, batch table wizard. Out of the box, its ready to perform highspeed gc utilizing the latest in ultra narrowbore capillary columns. Rapid oven cooling, high performance flow control and backflush technology allow the user to shorten analysis times greatly for significant gains in productivity. Gc2010 plus injectors all units including the column oven, flow controller and sample injection unit are comprehensively optimized at the design stage to achieve worldclass precision. The gc 2010 plus enables reliable, highprecision trace analysis with outstanding repeatability, utilizing the full suite of detectors that feature bestinclass sensitivity. The shimadzu gc 2010 plus with a hs20 headspace unit enables rapid identification and quantitation of very low concentrations of residual solvents.

Hope youll solve this problem because it could be useful to me as well in the future. Gc 2010 plus gc 2010 month date apr 2324 may 0708 aug 2728 oct 2930 course highlights fundamentals for gc 2010 series operation cmyk csc training schedule shimadzu analytical, india 11. Application food safety for packaging material hs20 gc. Combining these attributes with two and three times the sensitivity for octafluoronapthalene ofn in electron impact ei and negative chemical ionization nci modes respectively over the gcmsqp2010 makes the gcmsqp2010 plus the ideal instrument for. Descended from the gcmsqp2010s, it combines the benefits of economy, simple operation and enhanced performance. Need help for shimadzu gc 2010 manual chromatography forum. Apr 28, 2010 hello, i need your help, is there anyone have english shimadzu gc 2010 manual. Dataapex shimadzu gc2010 apcafc user manual pdf download. Gc troubleshooting gc troubleshooting hints and tips.

Shimadzu gc2010 since introducing our first gas chromatograph over 50 years ago, shimadzu has set the standard for gc power, speed and precision. One column is not sufficient to achieve baseline separation for some targeted solvents. Gc2010 plus capillary gas chromatograph gc2010 plus printed in japan 36550532250ait company names, productservice names and logos used in this publication are trademarks and trade names of shimadzu corporation or its affiliates, whether or not they are used with trademark symbol tm or. Shimadzus newgeneration gc2025 capillary gas chromatograph minimizes environ. Shimadzu gc2010 plus the gc 2010 plus enables reliable, highprecision trace analysis with outstanding repeatability, utilizing the full suite of detectors that feature bestinclass sensitivity. Highend gas chromatograph gc2010 plus capillary gc. Labsolutions is equipped with a pdf output function as.

C184e019j gc2010 plus capillary gas chromatograph gc2010 plus printed in japan 36550551230ait company names, productservice names and logos used in this publication are trademarks and trade names of shimadzu corporation or its affiliates, whether or not they are used with trademark symbol tm or. The new ecd has been optimized at all levels, enabling truly worldclass performance. Gc2010, gc 2010 plus, gc2010 pro, gc2014, gc2014c and. Make sure that data file is saved to the correct directory by clicking on file name and selecting right folder. In addition, rapid oven cooling and backflush technology shorten analysis time greatly for significant improvements in productivity. Select wide when connecting the gc to the cr8acr7acr7a plus. It enables full instrument control of and data acquisition from the shimadzu gc 2010. Following is an analysis example of nc12, 14, and 16 in nheptan solution. Shimadzu scientific us webstore exhaust duct gc2010 plus.

Today, the gc 2010, in conjunction with gcsolution software, is the most powerful gas chromatography analysis system available in the world, delivering faster analysis, reduced downtime, superior. To avoid the inconvenience of changing column, an automated parallel dualcolumn hs gc technique was developed in this study to separate a mixture of. Gas chromatograph mass spectrometer gcmstq8040 20 pages. New applications using gc bid detector bid 2010 plus of tracera is a novel universal detector based on dielectric barrier plasma ionization. Gc2010 plus shimadzus new flagship model, the gc2010 plus, is the highest performance capillary gc available in the world, providing precise, highspeed tracelevel analysis in a wide range of applications. Chromatographie chromatography vogel communications group. The new tracera gc system is now ready to solve your trace analysis needs. Note that shimadzu does not have any obligation concerning the. This gc unit has particularly distinguishing features.

High sensitivity detection sensitivity over 100x higher than tcd, 2x higher than fid 2. The control module enables direct control of chromatographs. When the hs20, gc 2010 plus, and a workstation labsolutions lc gc are used in combination, everything including the headspace conditions and gc conditions can be controlled from the workstation, which makes it easy to configure settings and operate the system. View and download shimadzu gc2014 instruction manual online. Gc2010 plus gas chromatograph, shimadzu out of the box, the gc2010 plus is ready to perform highspeed gc utilizing the latest in ultra narrowbore capillary columns the fourth generation advanced flow controller delivers up to 1200 mlmin, 140 psi of pressure and supports split ratios of 9999. Gc 2010 plus gas chromatograph, shimadzu out of the box, the gc 2010 plus is ready to perform highspeed gc utilizing the latest in ultra narrowbore capillary columns the fourth generation advanced flow controller delivers up to 1200 mlmin, 140 psi of pressure and supports split ratios of 9999. This is a working shimadzu gc 2010 gas chromatograph w gcmsqp2010 plus mass spectrometer system. Shimadzu gc 2010 since introducing our first gas chromatograph over 50 years ago, shimadzu has set the standard for gc power, speed and precision.

Shimadzu gc2010 gas chromatograph w gcmsqp2010 plus. Regarding the flame stability problem, i have a shimadzu gc2010 plus ecdfid with 2 injectors and i didnt have any problems with the flows yet, but im using it only since september. The gc 2010 plus reduces analysis time, improves work efficiency, and. Capillary gc2010 plus shimadzu europa pdf catalogs. A shimadzu gc 2010 plus equipped with an advanced flow controller afc, a splitsplitless injector spl and a flame ionization detector fid was used for this study. Ecd 2010 exceed provides solutions for pcb analysis.

Gas chromatograph accessories and supplies shimadzu. Used shimadzu gas chromatograph, model gc 2010 plus, with aoc20i auto injector and dell pc, item specifications modeltype. Supported modules by the shimadzu gc 2010 2014 instrument control driver module name unit gc 2010 gc 2010 plus gc 2014 min. Aoc20i, 20s configured with the gcmstq8030 and gcmsqp2010 series.

Fast oven heating and cooling reduces the analysis time and allow high sample throughput. Shimadzu gc 2010 manual injection scientist solutions. After you login, the data acquisition software will automatically come up. The gc 14b series gas chromatograph, which is controlled by microcomputer, is a multipurpose gas chromatograph exhibiting high performance. With advanced flow technology capillary gas chromatograph system the shimadzu gc 2010 plus represents a new generation in top end capillary gc analysis, redefining sensitivity limits for trace analysis, fast gc applications, and easy, robust operation. C10ge035 solutions for plastic evaluation shimadzu. Gc2010 plus datasheet shimadzu scientific instruments. Tracera makes it possible to conduct many kinds of applications and achieve simple and high sensitive analysis. When performing highsensitivity analysis on a gc2010 plus or even. Realize dramatic improvements in productivity with the gc 2010 plus. Jul 22, 2010 shimadzu corporation, one of the worlds leading manufacturers of analytical instrumentation has launched a new gcmsqp 2010 ultra gas chromatograph mass spectrometer gc ms offering the highest. With advanced flow technology capillary gas chromatograph system the shimadzu gc2010 plus represents a new generation in top end. C 0 to 970 kpa direct connection with capillary column 50 to 350. Gas chromatograph accessories and supplies shimadzu pdf.

For example, replacing septa or liner at regular intervals and keeping the injector and detector clean and wellmaintained shoud solve many problems. Shimadzu corporation international marketing division shimadzu scientific instruments, inc. Shimadzu shimadzu corporation this website uses cookies to offer you a better browsing experience and to analyze our traffic. Shimadzu gc2010 plus and shimadzu gc2014 in agilent openlab cds. Shimadzu gc 201x 4 using the control module description description of the method this description is not sent to or read from gc, it serves for the information purposes only. Many gc problems can be prevented if the column is properly installed and gc is maintained routinely. All units including the column oven, flow controller and sample injection unit are comprehensively optimized at the design stage to achieve worldclass precision. Gas chromatography gc protocol shimadzu gc 2010 page 3 of 6 gas chromatography protocol.

The gc2010 plus enables reliable, highprecision trace analysis with high repeatability, utilizing detectors such. Thank you very much for your purchase of shimadzu s gc 14b series gas chromatograph. Shimadzu gc 2010 manual injection i am still a beginner with limited experience on gc instruments. View and download shimadzu gc 2014 instruction manual online. Realize dramatic improvements in productivity with the new gc2010 plus. Ethanol determined by gas chromatography gc a gc2010 plus or gc2014 with the addition of a headspace autosampler can be used for analysis of diacetyl, as described in section 2. The newly designed capillary ecd cell incorporates shimadzu s proprietary contact free technology. The fourth generation advanced flow controller delivers up to 1200 mlmin, 140 psi of pressure and supports split ratios of 9000. The gc 2010 pro represents a new generation in routine gc. Agilent 5973 varian saturn 2000 fid ms ethanolamine 116, 117 alanine ala a, 88, 70 1 0. Nmr bruker avance 400 400 mhz and gc ms shimadzu gc 2010 plus coupled to a mass spectrometer, shimadzu gcmsqp 2010 ultra were used for characterization of isolated products. Supports dualinjection system and a maximum of four gc 2010 detectors or two non gc 2010 detectors.

This technology significantly reduces deposition of sample residue on the detector and radiation source. The gc2010 plus reduces analysis time, improves work efficiency, and. Minutes detector response shimadzu gc2010 plus for measurement of alcohol content. Advanced standard model with benefit of economy the gcms qp2010se is our advanced standard gas chromatograph mass spectrometer. Gc 2010 plus capillary gas chromatograph gc 2010 plus printed in japan 36550532250ait company names, productservice names and logos used in this publication are trademarks and trade names of shimadzu corporation or its affiliates, whether or not they are used with trademark symbol tm or. The gcmsqp2010 plus comes equipped with a variety of new features and an expanded mass range 1. Combining these attributes with two and three times the sensitivity for octafluoronapthalene ofn in electron impact ei and negative chemical ionization nci modes respectively over the gcmsqp2010 makes the gcmsqp2010 plus the ideal instrument for characterizing complex.

Shimadzu gcms users booklet 1 log in, using your login name and password. Gcmsqp2010 ultra gas chromatograph mass spectrometer youtube. Gc2010 plus capillary gc rapid oven cooling with the addition of a new cooling fan and superior air flow optimization, the oven cooling speed has been dramatically improved 450 c 50 c cooling time. Hs20 headspace autosampler paired with gc 2010 plus shimadzu corporation, japan was used in this study.

The gc2010 gas chromatograph is a qualitative and quantitative analysis system. The shimadzu gc 2010 control module was developed upon mutual agreement with the shimadzu company and is based on detailed documentation, which they provided. Select from three injection units to suit the needs of your analysis. Based on gc 2010 plus technology, it combines easy operation with efficient analysis and excellence in sensitivity and precision. The enhanced maximum column flow enables a variety of columns to be selected. The gc outputs square root of the original signal to the chromatopac, and the received signals are squared in the chromatopac. The gc2010 plus represents a new generation in top end capillary gc. This brochure introduces various accessories and supplies that support shimadzu gc instruments. Gas chromatograph mass spectrometer gcmstq8040 shimadzu. Highend gas chromatograph gc 2010 plus capillary gc. Rapid oven cooling, high performance flow control and backflush technology allow the user to shorten analysis times greatly for significant gains in. Gc with headspace analysis of 10 ul of 1,000 ugml of residual solvent standards gc 2010 plus with hs20 headspace sampler.

I get japanese version manual in my laboratory, but it is too difficult for me to understand japanese kanji. Shimadzu corporation, one of the worlds leading manufacturers of analytical instrumentation has launched a new gcmsqp 2010 ultra gas chromatograph mass spectrometer gc ms offering the highest. Method setup gc flow 1 this tab governs the settings concerning the injection port of the shimadzu gc 201x chromatograph. This system utilizes the new barrier discharge ionization detector technology coupled with a gc 2010 plus capillary gas chromatograph to create a gc. However, now i will be using the gc routinely and am trying to use a shimadzu gc 2010. Productivity and sample throughput can be dramatically. Gcmsqpq2010 plus gcmsqp2010s the most sensitive gcms on the market, shimadzus gcmsqp2010 plus delivers better performance and reliability with unsurpassed hardware capabilities and powerful. The gc 2010 plus enables reliable, highprecision trace analysis with high repeatability, utilizing detectors such as fid and fpd that feature bestinclass sensitivity.

921 698 592 258 490 932 1046 836 270 945 1270 781 538 1154 521 962 1562 1201 1035 903 415 1457 535 1325 527 1436 79 1257